The rules in short

The 2025 California Energy Code took effect January 1, 2026. Section 150.2(b)1I covers reroofs of low-slope roofs (pitch under 2 in 12) when more than 50 percent of the roof is replaced (§150.2):
- Cool roof, zones 4 and 6 to 15: aged solar reflectance at least 0.63 and thermal emittance at least 0.75, or an SRI of at least 75.
- Insulation, zones 1, 2, 4 and 8 to 16: R-14 continuous insulation or a roof assembly U-factor of 0.039 or less. Zones 3 and 5 to 7 have no requirement.
Eichler areas by climate zone
Zones come from the Energy Commission's ZIP table (CEC JA2). A few ZIPs straddle two zones, so check your exact address with the CEC climate zone tool.
| Area | Climate zone | Cool roof required? | R-14 required? |
|---|---|---|---|
| Palo Alto, Sunnyvale, Cupertino, Mountain View, San Jose | 4 | Yes | Yes |
| Walnut Creek, Concord | 12 | Yes | Yes |
| San Rafael, Terra Linda, Lucas Valley | 2 | No | Yes |
| San Mateo Highlands, Foster City, San Francisco, Oakland, Castro Valley | 3 | No | No |
Sunnyvale ZIPs may span zones 3 and 4, and unincorporated areas of Alameda and Marin counties span more than one zone (CEC). Check before you pick a roof.
Trading insulation for reflectance
In zones 2, 4 and 8 to 15, more insulation lowers the reflectance you need (§150.2, Table 150.2-E):
| Insulation above the deck | Minimum aged solar reflectance |
|---|---|
| R-16 | 0.60 |
| R-18 | 0.55 |
| R-20 | 0.50 |
| R-22 | 0.45 |
| R-24 | No requirement |
The R-24 row is the one Eichler owners in zones 4 and 12 ask about. It lets you keep a dark gravel or cap sheet look if you're willing to add thicker insulation, which raises the roof edge.
Exceptions that matter on Eichlers
- Existing insulation. If the roof already has R-10 or more continuous insulation, the R-14 rule doesn't apply. In zones 1, 2, 4 and 8 to 10, an existing assembly at U-0.056 or with R-19 between rafters also qualifies (§150.2).
- Equipment and walls. Where rooftop equipment or an adjoining wall or parapet leaves too little room for flashing, insulation can drop to R-4 in those spots.
- Heavy roofs and solar. Roofs weighing 25 pounds per square foot or more, and area under integrated solar, are exempt from the cool roof rule (CEC compliance manual).
What this means for your roof choice
- Zone 4 or 12: a white foam roof or white single-ply over insulation board meets both rules in one job. Built-up roofs work with a reflective cap sheet or coating, or with R-24 under them. Compare systems.
- Zone 2: no color rule, but plan on R-14. In San Rafael, ask how much the edge will rise, since raising a roof structure more than 6 inches goes to design review (SRMC 14.14).
- Zone 3: you can choose freely. Insulation is still the best upgrade you'll get the chance to make. Insulation.
Every roofer we work with is licensed and insured.
Book a free roof inspectionFrequently asked questions
What counts as a low-slope roof?
A roof with a pitch under 2 in 12 (2025 Energy Code §150.2). Most Eichler flat roofs qualify. Some Eichler gables are steeper, often around 3 in 12 (Palo Alto guidelines), and steep-slope rules apply to those parts.
Does a repair trigger these rules?
The rules apply when more than half the roof is replaced (2025 Energy Code §150.2). The Energy Code treats replacing roofing as an alteration, not a repair (CEC compliance manual).
Can I keep a dark roof in climate zone 4?
Yes, with more insulation. With R-24 or more above the deck, the cool roof requirement drops away (2025 Energy Code §150.2).
Do solar panels count?
Roof area under building-integrated solar is exempt from the cool roof rule (CEC compliance manual).
Sources
- 2025 California Energy Code §150.2(b)1I, roof alterations (Energy Code Ace)
- CEC Joint Appendix JA2 climate zones by ZIP (docketed TN 223245-2)
- California Energy Commission: Climate zone tool and maps
- California Energy Commission: 2022 Single-Family Residential Compliance Manual, Ch. 9 Additions, Alterations, Repairs
- San Rafael Municipal Code ch. 14.14: Eichler and Alliance Homes overlay
- Palo Alto Eichler Neighborhood Design Guidelines (adopted Apr 2, 2018, Res. 9748)
- California Energy Commission: 2025 Single-Family Compliance Manual, Ch. 9
Sources reviewed November 17, 2026. Confirm permits, design rules and requirements with your contractor and your city or county. This page is general information, not legal or insurance advice.