How it's built
Asphalt sheets with polymer modifiers, usually two plies, applied with a torch or cold adhesive, and topped with granules, gravel or a coating for sun protection (Roofing Survival Guide).
Numbers
| Measure | Figure | Source |
|---|---|---|
| Reflectance, mineral surface | 0.10 to 0.20 | Cool California |
| Reflectance, white coating | 0.60 to 0.75 | Cool California |
| Life expectancy | 10 to 30 years | Cool California |
The drainage caveat
A built-up roofer on the Peninsula told the Eichler Network that granulated mod-bit and cap sheet "does not hold up well with ponding water" on flat Eichlers, though it's fine where the roof drains (Lost in the Dark No More). If your roof ponds, fix the slope or choose a system that tolerates it. Drainage.
Meeting Title 24
A mineral surface won't meet the cool roof rule in zones 4 and 12. Use a rated reflective cap sheet or coating, or add insulation per the trade-off table. Climate zones.
Every roofer we work with is licensed and insured.
Book a free roof inspectionFrequently asked questions
Is torch-down safe on an Eichler?
Torch-applied sheets use an open flame on a wood-deck house, so ask about the roofer's fire-safety practice, or ask for a cold-applied or self-adhered product instead.
Sources
- Eichler Network: Roofing Survival Guide
- Cool California (California Air Resources Board): Roof Product Comparison
- Eichler Network: Lost in the Dark No More (reroofing systems and installers)
Sources reviewed November 17, 2026. Confirm permits, design rules and requirements with your contractor and your city or county. This page is general information, not legal or insurance advice.